Safe and reliable protection:
HP9117C series use DSP control technology,double-conversion on-line design,The HP9117C UPS resolves utility power problems and delivers superior power protection for IT and networking equipment ,medical systems,manufacturing process control,or anywhere critical equipment and applications require clean,continuous power.
Key Features:
1.Protects against downtime, data loss and process interruption by providing continuous, clean power.
2.Offers premium performance with a 0.9 power factor and >95% efficiency.
3.Increases battery service life and system uptime with ABM battery charging technology.
4.Enables prolonged runtime of essential equipment during power outages by allowing for orderly, remote shutdown of non-critical systems or processes.
5.Provides installation flexibility with a choice of rack or tower designs, both conserving valuable space.
6.Can replace batteries online, convenient for user to use.
7.Enhanced monitoring and configuration capability through easily navigated multilingual graphical LCD display.
- Parameter
Model | HP9117C 0.7-3KVA | ||||||||||
0.7KT/0.7KR | 0.7KT-XL/0.7KR-XL | 1KT/1KR | 1KT-XL/1KR-XL | 1.5KT/1.5KR | 1.5KT-XL/1.5KR-XL | 2KT/2KR | 2KT-XL/2KR-XL | 3KT/3KR | 3KT-XL/3KR-XL | ||
Capacity | 0.7KVA/0.63KW | 1KVA/0.9KW | 1.5KVA/1.35KW | 2KVA/1.8KW | 3KVA/2.7KW | ||||||
Nominal Voltage | 100/110/120/127VAC or 200/208/220/230/240VAC | ||||||||||
Nominal Frequency | 50/60 Hz | ||||||||||
Input | |||||||||||
Voltage Range | 60-138VAC or 115-276VAC | ||||||||||
Frequency Range | 50HZ:(46~54HZ);60HZ:(56HZ~64HZ) | ||||||||||
Power Factor | >0.98 | ||||||||||
Output | |||||||||||
Voltage Precision | 100/110/120/127VAC 2%) or 200/208/220/230/240VAC (±2%) | ||||||||||
Frequency Precision | 50Hz/60Hz±0.05Hz | ||||||||||
Power Factor | 0.9 | ||||||||||
Harmonic Distortion | Linear Load<3% Non-Linear Load<5% | ||||||||||
Overload Capacity | 100%~102% overload warning;102%~129% 12s; 130%~149% 2s; ≥150% 100ms | ||||||||||
Current Crest Ratio | 3:1 | ||||||||||
Transfer Time | 0ms AC→DC (± ( ) | ||||||||||
Battery | |||||||||||
DC Voltage | 24VDC | 36VDC | 48VDC | 96VDC | 96VDC | ||||||
Recharge Time | 5 hours to 90%(it mean standard model which battery inside the UPS) | ||||||||||
Charge Current | 1A | 4A/8A(option) | 1A | 4A/8A(option) | 1A | 4A/8A(option) | 1A | 4A/8A(option) | 1A | 4A/8A(option) | |
Panel Display | |||||||||||
LCD | UPS status, input/output voltage and frequency, battery voltage, capacity, load, temperature, history records | ||||||||||
Language | English, French, German, Russian, Spanish | ||||||||||
Communications | |||||||||||
Communications Interface | Optional: SNMP card,AS400 card or the CMC provide software, EPO ,USB port | ||||||||||
Working Environment | |||||||||||
Temperature | 0 40℃ | ||||||||||
Relative Humidity | 0 95% (Non-condensing) | ||||||||||
Storage Temperature | -25℃ 55℃ | ||||||||||
Elevation | <1500 m | ||||||||||
Noise Level(1m ) | <45dB | <50dB | |||||||||
Physics Characteristic | |||||||||||
Weight (KG) | N.W | 13 14 | 9 10 | 15 16 | 8.5 9 | 18 18.5 | 10 10.5 | 33 10.5 | 16.5 11.5 | 34 11.5 | 17 12.5 |
G.W | 15 16 | 11 13 | 17.5 17.5 | 11 11.5 | 20 20.5 | 12 12.5 | 35 12.5 | 18.5 13.5 | 36 13.5 | 19 14.5 | |
Dimensions: ( Wx D x H )mm | |||||||||||
Main unit(Tower) | 158X355X250 | 158X385X250 | 158X433X250 | 220X410X345 | 220X410X345 | ||||||
Main unit(Rack mount) | 482.6X450X89(2U) |